All Issue

2022 Vol.16, Issue 4 Preview Page

Research Article

30 August 2022. pp. 285-295
Abstract
References
1
Choi, H.N., Lee, J.W., Jia. R., Kim, D.H., Na, H.S., Kim, T.Y. (2020). Development of Supply Ventilation Strategy to Reduce PM2.5 in School Classrooms. J. of the AIK, 36(9), 119-129.
2
Jafari, M., Afshin, H., Farhanieh, B., Bozorgasareh, H. (2015). Numerical aerodynamic evaluation and noise investigation of a Bladeless fan. J. Appl. Fluid Mech., 8, 133-142.
3
Jafari, M., Afshin, H., Farhanieh, B., Bozorgasareh, H. (2016a). Experimental and numerical investigation of a 60 cm diameter bladeless fan. J. Appl. Fluid Mech., 9, 935-944. 10.18869/acadpub.jafm.68.225.24081
4
Jafari, M., Afshin, H., Farhanieh, B., Sojoudi, A. (2016b). Numerical investigation of geometric parameter effects on the aerodynamic performance of a Bladeless fan. Alexandria Eng. J., 55, 223-233. 10.1016/j.aej.2015.11.001
5
Jung, J.W., Lee, H.K. (2010). Study on the Characteristics of Air quality in the Classroom of Elementary School and Its Control Methods. J. of the KSEE, 32(4), 311-322.
6
Li, G., Hu, Y., Jin, Y., Setoguchi, T., Kim, H.D. (2014). Influence of Coanda surface curvature on performance of bladeless fan. J. Therm. Sci., 23, 422-431. 10.1007/s11630-014-0725-3
7
Ravi, D., Rajagopal, T.K.R. (2022). Numerical Investigation on the Effect of Geometric Shape and Outlet Angle of a Bladeless Fan for Flow Optimization using CFD Techniques. International Journal of Thermofluids, 15, DOI: 10.1016/j.ijft.2022.100174.
8
Park, S.H., Ahn, N.H., Lee, Y.J. (2020a, April). A Study on Applicability of Window Frame Integrated Ventilation System Considering Airtightness of Balcony. Paper presented at the Conference of the AIK 2020: AIK, 40(1), 296-297.
9
Park, S.H., Ahn, N.H., Lee, Y.J. (2020b, June). Evaluating the Applicability of a Window Frame Integrated Detachable Ventilation System for Ventilation of the residential Buildings. Paper presented at the Conference of the SAREK 2020: SAREK, 200-203.
10
Park, S.H., Ahn, N.H., Lee, Y.J., Jung, H.Y., Lee, H.S., Kim, T.W. (2021a, October). A Study on the Ventilation Performance Evaluation of the Window Sash Frame Integrated Ventilation System Applied to a Living Space. Paper presented at the Conference of the AIK 2021: AIK, 41(2), 630-631.
11
Park, S.H., Ahn, N.H., Lee, Y.J., Park, Y.M., Kang, S.B., Kim, Y.A. (2021b, April). A Feasibility Study of Developing a Window Base Frame Integrated Compact Ventilation System. Paper presented at the Conference of the AIK 2021: AIK, 41(1), 343.
12
Lee, P.S. (2012). A Study on the Adequate Required Amount of Ventilation for Enhanced Indoor Air Quality in an Elementary School Classroom. Master thesis. Seoul National University of Science and Technology Graduate School of Energy and Environment. Seoul, Korea.
13
Dyson Technologies Limited. (2013). Korean Patent No. 10-1293593, Daejeon, Korean Intellectual Property Office.
14
KS F 2603. (2021). Method for measuring amount of room ventilation (carbon dioxide method).
15
Enforcement Rule of the School Health Act. (2022). Ordinance of the Ministry of Education No. 270.
16
변국영, 「실내 환기기준 4배로 높여야 비말 충분히 제거」, 에너지데일리, 2020, http:// www.energydaily.co.kr, 2022. 08. 11.
Information
  • Publisher :Korean Institute of Architectural Sustainable Environment and Building Systems
  • Publisher(Ko) :한국건축친환경설비학회
  • Journal Title :Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
  • Journal Title(Ko) :한국건축친환경설비학회논문집
  • Volume : 16
  • No :4
  • Pages :285-295
  • Received Date : 2022-07-25
  • Revised Date : 2022-08-26
  • Accepted Date : 2022-08-26
Journal Informaiton Journal of Korean Institute of Architectural Sustainable Environment and Building Systems Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
  • NRF
  • KOFST
  • KISTI Current Status
  • KISTI Cited-by
  • crosscheck
  • orcid
  • open access
  • ccl
Journal Informaiton Journal Informaiton - close