All Issue

2018 Vol.12, Issue 1 Preview Page
February 2018. pp. 72-85
Abstract
References
1
보건복지부, 질병관리본부, 메르스 국내발생현황(2015)
2
Gilkeson C. A, Camargo-Valero M. A, Pickin L. E, Noakes C. J, Measurement of ventilation and airborne infection risk in large naturally ventilated hospital wards, Building and Environment (2013), pp 35-48
10.1016/j.buildenv.2013.03.006
3
Hua Qian, Yuguo Li, Peter V. Nielsen, Xinhua Huang, Spatial distribution of infection risk of SARS transmission in a hospital ward, Building and Environment (2009), pp 1651-1658
10.1016/j.buildenv.2008.11.002
4
Deenadayalan Chandran, Mohamedanas Patni, Assessment of airborne infection control practices in the pulmonary medicine ward in a tertiary-care hospital of south Gujarat, International Journal of Medical Science and Public Health (2015)
5
Cheng-Hsin Chang, Chang-Chuan Chan, Kuang-Jung Cheng, Jin-Shian Lin, Computational fluid dynamics simulation of air exhaust dispersion from negative isolation wards of hospitals, Engineering Applications of Computational Fluid Mechanics(2011), pp 276–285
10.1080/19942060.2011.11015370
6
Chun Chen a, Wei Liu, Chao-Hsin Lin, Qingyan Chen, A Markov chain model for predicting transient particle transport in enclosed environments, Building and Environment (2015), pp 30-36
7
Carla Baloccoa, Pietro Liob, Assessing ventilation system performance in isolation rooms, Energy and Buildings (2011), pp 246–252
8
Jose Manuel Villafruel, Francisco Castro, Julio Francisco San Jose, Julien Saint-Martin, Comparison of air change efficiency, contaminant removal effectiveness and infection risk as IAQ indices in isolation rooms, Energy and Buildings (2013), pp 210–219
9
K.W.D. Cheong, S.Y. Phua, Development of ventilation design strategy for effective removal of pollutant in the isolation room of a hospital, Building and Environment (2006), pp 1161–1170
10.1016/j.buildenv.2005.05.007
10
Hua Qiana, Yuguo Lia, Peter V. Nielsen, Carl E. Hyldgaard, Dispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system, Building and Environment (2008), pp 344–354
11
Hua Qian, Yuguo Li, W.H. Seto, Patricia Ching, W.H. Ching, H.Q. Sun, Natural ventilation for reducing airborne infection in hospitals, Building and Environment (2010), pp 559–565
10.1016/j.buildenv.2009.07.011
12
S.S. Magill, J.R. Edwards, W. Bamberg, Z.G. Beldavs, G. Dumyati, M.A. Kainer, R. Lynfield, M. Maloney, L. McAllister-Hollod, J. Nadle, S.M. Ray, D.L. Thompson, L.E. Wilson, S.K. Fridkin, Multistate point-prevalence survey of health care-associated infections, N. Engl. J. Med., 370 (2014), pp.1198-1203
10.1056/NEJMoa130680124670166PMC4648343
13
Yang-Cheng Shiha, Cheng-Chi Chiua, Oscar Wang, Dynamic airflow simulation within an isolation room, Building and Environment, (2007) 3194–3209
10.1016/j.buildenv.2006.08.008
14
H. Qian, L. Liu, Q. Zhou, Numerical investigation of airborne infection in naturally ventilated hospital wards with central-corridor type, Indoor and Built Environment (2016)
Information
  • Publisher :Korean Institute of Architectural Sustainable Environment and Building Systems
  • Publisher(Ko) :한국건축친환경설비학회
  • Journal Title :Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
  • Journal Title(Ko) :한국건축친환경설비학회논문집
  • Volume : 12
  • No :1
  • Pages :72-85
  • Received Date : 2018-02-07
  • Revised Date : 2018-02-27
  • Accepted Date : 2018-02-27
Journal Informaiton Journal of Korean Institute of Architectural Sustainable Environment and Building Systems Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
  • NRF
  • KOFST
  • KISTI Current Status
  • KISTI Cited-by
  • crosscheck
  • orcid
  • open access
  • ccl